ANALYZERS
 
Our product range :
  • O2/CO2 analyzers + O2 analyzer
  • Ethylene analyzer
  • Temperature measurement / Can modules
  • Pressure measurement
  • NH3 analyzer
O2/CO2 + O2 analyzer
  • Accurate and reliable in O2/CO2 readings;
  • Large display
  • Internal pump
  • Robust and portable
  • Easy to calibrate and to operate
  • Up to 32 measurement to be stored in memory
  • Universal rechargeable longlife batteries
 
PORTABLE O2/CO2 analyzer
Models
O2 /CO2  analyzers
 
 
O2/CO2 analyzer Type A
O2%range 0-25%
CO2%range 0-10%
No outputs, only used as portable analyzer
O2/CO2 analyzer Type A- H CO2
O2%range 0-25%
CO2%range 10-25%
No outputs, only used as portable analyzer
O2/CO2 analyzer Type G
O2%range 0-25%
CO2%range 0-10%
Portable analyzer with 4-20m Amp outputs
O2/CO2 analyzer Type G- H CO2
O2%range 0-25%
CO2%range 10-25%
Portable analyser with 4-20m Amp outputs
Input
100-240V AC 50/60Hz 800mA
Output for type G
4-20mA/0-20mA / CAN OPEN
Integrated O2 analyzer + display + pump and flow sensor + output
Electronic print on which the  O2 analyzer  is mounted + pump + flow sensor,
Integrated O2 analyzer + display + output
Electronic print with the  O2 analyzer + display  without pump + flow sensor,
Integrated O2/CO2 analyzer with outputs
Combined electronic print on which the  O2/CO2 analyzer  without case is mounted + pump + flow sensor,
Size in cm
12x18,5x7,5 
Weight
0,6 kg
Power supply
uni. rechargeable NiMH bat.
Input
100-240  AC 50/60 Hz 800 mA
Standard
belt and tube with filter
 
PORTABLE O2 analyzer
Size in cm
12x18,5x7,5 
Weight
0,6 kg
Power supply
uni. rechargeable NiMH bat.
Input
100-240  AC 50/60 Hz 800 mA
Standard
belt and tube with filter
 
ethylene analyzer
.The MACView®-Ethylene Oxide (EtOx) Analyser is an extreme sensitive ethylene Oxide measurement device suitable for measurement in warehouses, containers and confined spaces to protect human from high concentrations of Ethylene Oxide (EtOx). Levels around 1 ppb resolution can be measured. The system can be extended by adding O2 and CO2 sensors, the possibility of syringe injection, and the Web Based Monitoring software that transferred data fully automatically. No difficult software anymore. A GPRS, UMTS or Ethernet modem is standard included. An external and simple system for easy calibration is optional available for the portable system. 
 
technical details
ethylene analyzer
Type of instrument
MACView®-EtOx Analyser, for ethylene oxide measurement based on the solid state 
Measurement range
0-5.000 ppb EtOx resolution 1 ppb max. inaccuracy ±0.5‰
Versions available
Portable version for handheld monitoring, measurement of containers / confined space
Fixed 19” version for fixed mounting to measure rooms of storages
Option for add a 2nd sensor
Optical O2 sensor measurement range 0 - 25% , 0.001% resolution < 1% O2
Option for add a 3th sensor
Optical CO2 sensor measurement range 0 - 0.2% 0 - 1% / 0 - 10% CO2 inaccuracy ±0.1%
Battery Pack (portable) 
Lithium-Ion 11.500 mAh,charged while system is running, approx. 12 hrs runtime @20°C
Working temperature
-10 + 50 degrees Celsius, relative humidity 5 - 99%, not condensed
Dimensions
Portable: Width 230 x Depth 405 x Height 180 mm
19” fixed version: Width 480 x Depth 350 x Height 301 mm
Weight
Portabe version: 11.3 Kg    Fixed 19” version: 12.8 kg
 
temperature measurement / CAN modules
The CAN module is an Store in house developed amplifier for 8 pc. Temperature PT100/PT1000 probes and optional 2 pc pressure sensors. The CAN module can be installed for 2 CA stores providing for each CA store a maximum of 4  temperature readings  and a pressure reading. The CAN modules are connected with each other via CAT5 or CAT 6 cable and connected to the Auto Store CMS system.
.
technical details
PT100
type
Resistance Temperature sensor with connection cable,
protection stainless steel tube made out of one part
working temperature
-5… + 100°C
classification
Class AA
diameter
Ø 5,0mm
cable
Shielded cable
length of cable
5m., 10m, 20m, 30m
Integrated O2/CO2 analyzer
with outputs
Combined electronic print on which the  O2/CO2 analyzer  without
case is mounted + pump + flow sensor
 technical details
CAN Module
type module
Storex  Can bus module
Amplifier for temperature sensors
Nr. of temperature sensors 8 pieces
Communication protocol Modbus TCP/IP
Cable Type Internet cable CAT5 / CAT6
Max. length of cable 50 mtr. between 2 modules
Option pressure sensor Each CAN module can be provided with max. 2 pc. pressure sensor for measurement pressure change in a CA room / leak testing
option case CAN modules mounted in IP casing
 
pressure measurement
.Pressure fluctuations in a CA room can cause problems to achieve the target values. Especially underpressure created by defrost & cooling actions or weather changes can affect the oxygen levels inside the CA room. To monitor and evaluate the pressure fluctuations Storex has developed the CAN module with high sensitive pressure measurement. The scale of the measurement has an accuracy of 1 Pa or 0,1 mm watergauge. The data of these measurements are collected on the PLC and send through internet communication into the cloud. Depending on the pressure fluctuations, the settings of the cooling installation needs to be adapted. CA rooms can handle pressure differences between outside and inside atmosphere of -80 upto 80 Pa. Of course this range depends on the configuration of the safety valve. Below a graph of the pressure monitoring during a specific period.
 
NH3 measurement
.As a natural cooling gas , NH3 is very efficient and has a low COP value. This cooling gas can be used directly (DX system) or indirectly (glycol system). NH3 is often used in larger projects because of the high investment of the equipment and installation. In case of a leakage the ammonia has a high impact on the environment. Even low concentrations from 5 ppm can be detected by a human nose and in high concentrations humans can suffer severe injuries. When the gas is used directly, the NH3 can cause damage to the stored fruits inside the CA room . NH3 damage presents it self first with the colouring of the skin of the fruit.  In case of conference pears the skin will turn black. To avoid such disasters Storex has integrated the NH3 into the adsorber software.  Depending on the measurement interval , each room will be measured on oxygen, carbondioxyde and ammonia. In case the treshold of ammonia is exceeded, the system sends an alarm to the operator by SMS and/or email. The operator can start remotely the areation of the specfiic storage room using the fan capacity of the scrubber. By usinig both fans of the scrubber, the ammonia is removed quickly and safely outside the building.  Our CMS, the central measurement system, analyse the gassample, detects the concentrations and sends the result of the measurement to our Autostore Measurement and Control  (AMC) which is located in the switchboard of the scrubber. The AMC decides which actions should be taken on room level. Below the overview of the CMS .