Knowledge-Center

The Fire triangle

A fire needs Heat, Fuel, and Oxygen to start and survive. Take any of these elements away to prevent ignition and avoid combustion.

Heat is needed to raise the fuel to its minimum ignition temperature.

Fuel must be available for ignition. It may be in the form of a solid, a flammable liquid, or gaseous state.

Oxygen, or any other oxidizer, combines with other elements provided by the fuel to feed the fire. Remove the oxygen, and the fire dies.

Always on oxygen reduction system

Storex's solution relies on hypoxic air for fire prevention via the use of controlled atmosphere technology, also known as oxygen reduction.

The system is based on a permanent reduction of the oxygen concentration in the protected spaces, thus eliminating one side of the fire triangle.

Traditional fire suppression systems extinguish fires after they are detected. Hypoxic air is able to prevent fires altogether.

Most fires require a Minimum Oxygen Concentration (MOC) of 17% by volume, depending on the fuel available.

Diluting the oxygen concentration to below the MOC hinders the reaction from generating enough energy to heat the fuel to the extent required for the self-propagation of the flame.

 
Key features
  • -Proprietary technology uses low pressure (< 1 bar) and PVC piping. No high pressure nozzles.
    -No discharge of harmful chemicals or asphyxiants, safe for humans and the environment.
    -Easily integrates into your existing HVAC systems for seamless operation.
    -Single machine can control multiple discrete or contiguous spaces.
    -Low O2 environment minimizes corrosion and reduces degradation of sensitive equipment and materials, while extending their usability.
    -fully redundant with the use of several combined machines
    -automated websystem with controls
    -phone and email alerts
    -system connected to fire panel
    -custom made installation

Why storex?

storex is the most experienced manufacturer of VSA hypoxic generators. The capacity of our modular VSA-hypoxic generators vary from 10-150m³ at a maximum of 3% O2 rest value. Our machines are build with First-class components, tested thoroughly according to specific procedures, from first class suppliers

   
 

Storex provides Full service; from engineering, design, installation and maintenance of oxygen reduction systems World wide: DESIGN, CONSTRUCTION and MAINTENANCE.

 

VSA vs CO2

No dangerous gasses
No lifethreatening extinquish gas

VSA vs sprinklers

Iets
Iets

Conventional Suppression